N95-Face Mask Niosh Approved N95 FDA Clear Surgical Mask N95 Dongguan Keyutai Mask Co., Ltd. , https://www.maskkytai.com
Determination of urethane residues in foods - liquid chromatography - tandem mass spectrometry
Food safety analysis workflow
Thermo Scientific Life Science MS not only has a long tradition of technology, but also continues to innovate. Quadrupole mass analysis of true conjugate hyperboloids that fits the perfect theoretical electric field of a textbook is used on all TSQ® triple quadrupole mass spectrometers. Since launching the world's first triple quadrupole MS/MS (TSQ®) mass spectrometer in 1980, TSQ® triple quadrupole mass spectrometer has been widely used in environmental protection, agriculture, quarantine, food safety, etc. Analytical testing, fully capable of testing routine testing of large-volume samples of crops, livestock and poultry products, dairy products and related processed foods, such as pesticide residues in food, veterinary drug residues, mycotoxins, additives, nutritional supplements and organic pollutants And other projects to help you easily meet the increasingly stringent regulatory requirements.
TSQ® Triple Quadrupole Mass Spectrometer and Thermo Fisher Food Safety Testing Strategy
summary
Carbamate pesticides are a new broad-spectrum insecticidal, acaricidal, and herbicide developed against the shortcomings of organochlorine and organophosphorus pesticides. Daily testing involves both plant source samples such as vegetables, fruits, and grains, as well as animal source samples such as honey and dairy products. This article has been simplified from SN/T 3156-2012 and is an instrumental method for the rapid detection of 14 carbamate pesticides, quantified by external standard method.
Pretreatment
For related reagent materials, standard configuration and reserves, and sample preparation methods, please refer to the above standards. For related instrument methods, please refer to this document. ( TSQ Triple Quadrupole Mass Spectrometer Concise Application Manual - Food Safety Testing )
instrument
The TSQ Triple Quadrupole LC/MS system is equipped with an ultra-high pressure liquid phase system.
Liquid phase condition
Mass spectrometry condition
SRM condition
Experimental result
Typical chromatogram (excerpt from SN/T3156-2012 appendix)
in conclusion
GB2763-2014 The maximum residue limit for carbamate pesticides is 0.01-1 mg/kg. This method can fully meet the requirements of domestic and international regulations for sensitivity and reproducibility of conventional regulations.