Ice Hair Removal,Ice Laser Hair Removal,Ice Therapy Hair Removal,Ice Cold Ipl Hair Removal Shenzhen Jie Zhong Lian Investment Co., Ltd. , https://www.szmeizon.com
1. The no welding titanium alloy main arm is adopted, so that the appearance is aesthetic and the rotation is more flexible and convenient.
2. The removable handle sheath can be disinfected at the high temperature of 135ºC.
3. The demolished panel made of imported material makes the light rays softer.
4. The imported switch power supply is adopted to control the voltage, making the work voltage permanently stable.
5. The special radiation filter reducing the heat to the minimum level.
6. The multi-flake retro reflector made of imported aluminum sheet has the features of no coating film and never fading.
7. Imported lamp receptacle, Tungsten halogen bulbs of international brand are adopted with the average service more than 1500 hours.
8. Light adjustment circuit adopts CPU control, enabling increase or decrease of illumination and boasting brightness memory.
9. One lamp holder with two bulbs enables automatic operation of the standby bulb in 1/2 second when the main bulb malfunctions, and it has indicators for the damage of main or standby bulb.
Model                                   AKL600/600-II Illumination(lux)                          140000≥Ec≥80000
140000≥Ec≥80000Color Temperature(K)                      4500±500 Color rendering index                      100≥Ra≥85 Diameter of Spot(mm)                     d10175±35 Depth of light beam(mm)                   ≥700 Brightness level adjustment                 CPU light-dimmer The value of the total irradiance              <6m W/m²lx (service range for temperature rise≤10ºC) Total irradiance(Temperature rise on the head  ≤600 W/m² Of patient under surgical operation≤2ºC) Diameter of lamp holder(mm)               600/600 Shift of major and stand by lamps             Automatic Bulb power W(24V)                         150/150 Power supply(AC)                          220±20% 50Hz Input power(VA)                         440+10% Minimum height for installation(mm)          2800~3200
Model                                   AKL600-II or AKL600-II(Wall) Illumination(lux)                          140000≥Ec≥80000 Color Temperature(K)                      4500±500 Color rendering index                      100≥Ra≥85 Diameter of Spot(mm)                     d10175±35 Depth of light beam(mm)                   ≥700 Brightness level adjustment                 CPU light-dimmer The value of the total irradiance              <6m W/m²lx (service range for temperature rise≤10ºC) Total irradiance(Temperature rise on the head  ≤600 W/m² Of patient under surgical operation≤2ºC) Diameter of lamp holder(mm)               600 Shift of major and stand by lamps             Automatic Bulb power W(24V)                         150 Power supply(AC)                          220±20% 50Hz Input power(VA)                           200+10% Minimum height for installation(mm)          2800~3200
Details:
Company Information:
Â
1. The no welding titanium alloy main arm is adopted, so that the appearance is aesthetic and the rotation is more flexible and convenient.
2. The removable handle sheath can be disinfected at the high temperature of 135ºC.
3. The demolished panel made of imported material makes the light rays softer.
4. The imported switch power supply is adopted to control the voltage, making the work voltage permanently stable.
5. The special radiation filter reducing the heat to the minimum level.
6. The multi-flake retro reflector made of imported aluminum sheet has the features of no coating film and never fading.
7. Imported lamp receptacle, Tungsten halogen bulbs of international brand are adopted with the average service more than 1500 hours.
8. Light adjustment circuit adopts CPU control, enabling increase or decrease of illumination and boasting brightness memory.
9. One lamp holder with two bulbs enables automatic operation of the standby bulb in 1/2 second when the main bulb malfunctions, and it has indicators for the damage of main or standby bulb.
Model                                   AKL600/600-II Illumination(lux)                          140000≥Ec≥80000
140000≥Ec≥80000Color Temperature(K)                      4500±500 Color rendering index                      100≥Ra≥85 Diameter of Spot(mm)                     d10175±35 Depth of light beam(mm)                   ≥700 Brightness level adjustment                 CPU light-dimmer The value of the total irradiance              <6m W/m²lx (service range for temperature rise≤10ºC) Total irradiance(Temperature rise on the head  ≤600 W/m² Of patient under surgical operation≤2ºC) Diameter of lamp holder(mm)               600/600 Shift of major and stand by lamps             Automatic Bulb power W(24V)                         150/150 Power supply(AC)                          220±20% 50Hz Input power(VA)                         440+10% Minimum height for installation(mm)          2800~3200
Model                                   AKL600-II or AKL600-II(Wall) Illumination(lux)                          140000≥Ec≥80000 Color Temperature(K)                      4500±500 Color rendering index                      100≥Ra≥85 Diameter of Spot(mm)                     d10175±35 Depth of light beam(mm)                   ≥700 Brightness level adjustment                 CPU light-dimmer The value of the total irradiance              <6m W/m²lx (service range for temperature rise≤10ºC) Total irradiance(Temperature rise on the head  ≤600 W/m² Of patient under surgical operation≤2ºC) Diameter of lamp holder(mm)               600 Shift of major and stand by lamps             Automatic Bulb power W(24V)                         150 Power supply(AC)                          220±20% 50Hz Input power(VA)                           200+10% Minimum height for installation(mm)          2800~3200
Details:
Company Information:
Â
Akl600-II Hospital Ceiling Medical Operating Theater Surgical Light with Ce
Model NO.: AKL600-II
Remote Control: Yes
Camera: Optional
Trademark: WANROOEMED
Transport Package: Wooden Pakage
Specification: ISO
Origin: China
HS Code: 9405409000
Model NO.: AKL600-II
Remote Control: Yes
Camera: Optional
Trademark: WANROOEMED
Transport Package: Wooden Pakage
Specification: ISO
Origin: China
HS Code: 9405409000
AKL 600-II Series Ceiling Medical Operating Theater Light with CE
Features:
 AKL 600-II Series Ceiling Medical Operating Theater Light with CE
Features:
Â