When walking with a rotary plough unit, the walking tractor should first engage the power output shaft and then hang up the work gear. When the clutch pedal is softly released, the hydraulic control handle is toggled, so that the rotary plough blade can be slowly inserted into the earth and then added. Big throttle until normal tilling depth. Before starting, it is forbidden to put the rotary plough into the soil and put it into the soil first, so as to avoid damage to parts. In the field work, attention should be paid to inspecting whether or not the working parts are noisy when they are running. Once discovered, they should immediately stop the inspection and find out the reasons for rectification. Both ends of the universal joint should be close to horizontal when working. When the joint is raised, the angle between the joint and the horizontal should be less than 30 degrees. If the horizontal level of the rotary tiller is not uniform, adjust the triangular pull rod so that the right pull rod can be shortened or stretched to reach horizontal level. Universal joints should be removed during daily transportation. Rotary ploughs must be raised when cornering and reversing the ground, otherwise the blade will be deformed or broken, and the rotary cultivator will be seriously damaged. When transferring the plot, the rotary plough should be raised to the highest position and the motive force of the PTO shaft should be cut off. If the transfer distance is long, it must be locked with a locking device. When the rotary plow is working for 3-4 hours, it is necessary to stop the inspection and clear the blade. During the inspection and clearance, many drivers did not put out any fire on the engine, but only stopped and stopped the plough, which often led to unfortunate incidents. The tractors that are involved in the accident are generally used cars. The parts are aging and have poor performance. In the event of an accident, the body tends to be in a head-to-tail posture. In addition, the gear lever that controls the clutch sleeve is too old and the body has too much vibration. Occasionally, the clutch sleeve will automatically fall and the rotary plough will automatically stop. To avoid this kind of accident, the driver must be optimistic about the parking situation when clearing the debris on the rotary plough. To be on the safe side, the gear lever controlling the clutch cover can be preliminarily tied with a rope to prevent it from moving. When cleaning, put a sickle with a handle more than two meters long, clean it away from the rotary plough 1 meter far away, and be vigilant, so that there is no danger. In order to reduce the direct contact of the crop straw and weeds with the coulter shaft, it is also possible to lengthen two bolts by about 10 centimeters when loading the coulter shafts to the left and right ends of the coulter, eliminating the phenomenon of reducing coulter shaft winding.
Germany imported beads
Imported French lens
mould Die-casting Eight edge type Revolving arm
Optional emergency power supply≥3 hours
The main features:
1)Ideal cold light effects
Using the new LED cold light source, ensure energy saving and environmental protection and long service life up to 80,000hours and more.
The temperature increase of surgeon`s head below 1℃. LED do not engender infrared ray and ultraviolet radiation, without the temperature
rise and tissue damage caused by halogen shadowless light, also it can accelerate the wound healing after surgery, and without Radiation pollution.
With color temperature constant and soft, LED is very close to the sunshine.
1) Excellent shadowless effect
Lamp with the most scientific radian and Multi point light source design, ensure better uniform illuminance. When the lamps are partially occluded,
also can achieve perfect shadowless effect.Lamp panel radius of gyration ≥182cm, the lamp can be pulled to vertical floor, convenient to any angle illumination.
2) Excellent deep lighting
It is based on modularize method by Computer Aided Design, focused to irradiating with more beams of LED. It produces the deep lighting which beams
more than 1200cm,the illumination of center up to 180,000Lux or more, and offer the color temperature that can be adjusted from 3700K to 5000K which
is close to sunshine. Absolutely, it really reflects the color of human tissue and satisfied by all kinds of operating light needs.
3) Advanced control system
The use of liquid crystal display button control, to meet the needs of the medical staff of different patients with the brightness of the operation.
It offers illuminance memory function.
It does not effect using when a single circuit or one bulb is broken.
4) Universal suspension system
Rotating arm, a new type of alloy material is made of eight edge type.
Balanced system using imported arm module, more than 5 group universal joints, every cantilever must has more than 3 joints which can be rotated in 360°,
The structure is light, easy to manipulate, accurate positioning, can provide the maximum range of regulation.The equipped with fatigue correcting unit and
fix position hand handle device, easy to fix position after long time use.
5) Modern laminar lamp
The thickest part of lamp-chimney is not more than 10cm.
The lamp-chimney is made of ABS, The handle on the central of lamp can be detachable, can take high temperature (≤ 134°C) sterilization treatment,
easily adjust, flexible fixed.
Mobile Type Operating Light,LED Examination Light,Mobile Operation LED Light,Mobile Stand Operating Light Shandong qufu healthyou Medical Technology co.,Ltd , https://www.kangerjian-medical.com
Rotary cultivator for safe rotation and cleaning