Medical gloves can be divided into examination gloves and surgical gloves.
Examination gloves are items worn by examiners on their hands during medical examinations to prevent cross-infection between physicians and patients. Clean, non-sterile, disposable use. It is used in direct or indirect contact with the patient's blood, body fluids, secretions, excreta, and articles obviously contaminated by body fluids.
The main material can be divided into PVC, nitrile, latex
Surgical gloves are used on the hands of operators to prevent bacteria from spreading to open surgical wounds and to prevent the body fluid of surgical patients from spreading to medical staff, thus playing a two-way biological protection role. This product is sterilized, sterile, and disposable.
The main material is latex
We are manufacturers and suppliers of the wholesale medical glove. In addition, we offer customizable services. Siny Medical can meet your needs. If you are in need of manufacturers and suppliers, please contact us.
Sterile Surgical Gloves, Hospital Gloves, Hand Gloves Medical, Disposable Medical Gloves Ningbo Siny Medical Technology Co., Ltd , https://www.sinymedical.com
1. The rat CD163 enzyme-linked immunoassay kit should be taken out from the refrigerated environment and should be used after equilibrating at room temperature for 15-30 minutes. If the enzyme-labeled coated plate is not used, the slats should be stored in a sealed bag.
Rat CD163 enzyme-linked immunoassay kit use precautions
Rat CD163 enzyme-linked immunoassay kit use precautions
2. Concentrated washing liquid may precipitate crystals. When diluted, it can be heated and dissolved in a water bath. The washing will not affect the results.
3. The sampler should be used for each step, and the accuracy should be corrected frequently to avoid test errors. The loading time is controlled within 5 minutes. If the number of specimens is large, it is recommended to use a gun to load.
4. Please make a standard curve at the same time of each measurement, and make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the first hole of the standard well), please first dilute the sample dilution with a certain multiple (n times) and then measure it. When calculating, multiply the total dilution by the total dilution. Multiple (×n×5).
5. The sealing film is for one-time use only to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the operation of the manual. The test results must be based on the reading of the microplate reader.
8. All samples, washings and various wastes should be treated as infectious materials.
9. The different batch components of this reagent should not be mixed.
10. If it is different from the English manual, the English manual shall prevail.
Storage conditions and expiration date
1. Kit storage: 2-8 °C.
2. Validity period: 6 months